ROHDE & SCHWARZ ZVB4 CALIBRATION and ROHDE & SCHWARZ ZVB4 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ROHDE & SCHWARZ ZVB4 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   ROHDE & SCHWARZ ZVB4   Description / Specification:   Spec Sheet 
ROHDE & SCHWARZ ZVB4 4 GHz Vector Network Analyzer

The R&S ZVB4 4 GHz Vector Network Analyzer series combines excellent performance with low weight and compact design. Intelligent and user-friendly functions offer maximum ease of operation. It allows the large number of measured quantities involved in multiport and balanced measurements to be handled easily, and also offer a variety of ways to optimize production sequences. High-speed parallel measurements can be performed because the generator signal can be output to multiple test ports simultaneously, plus data can be captured at multiple ports simultaneously and all displayed at the same time. For example, the R&S ZVB4 four-port version makes it possible to measure two two-port DUTs simultaneously, which doubles performance. It is also possible to measure and display the four reflection parameters S11 to S44 simultaneously on a four-port DUT (provided that DUT ports are uncoupled). This reduces measurement time by a factor of 4 compared with instruments featuring just one generator and a conventional switching technique. Specifications. Frequency range: 300 kHz to 4 GHz. Measurement time per point (CW mode, at 500 kHz IF bandwidth): < 4.5 µs. Measurement time (including any data transfer time): < 4.5 ms. Data transfer time: data transfer simultaneous with measurement. Dynamic range (at 10 Hz IF bandwidth): > 123 dB. Inherent noise: < –110 dBm. Power sweep range: –40 dBm to +13 dBm. IF bandwidths: 1 Hz to 500 kHz. Number of measurement points per trace: 1 to 60 001. Number of test ports: 2 or 4. Number of measurement and reference receivers: one measurement and one reference receiver per test port. Number of integrated generators: one generator per test port pair. Calibration techniques: TOSM, UOSM, TRL/LRL, TOM, TRM, TNA, automatic calibration unit. Number of traces, diagrams, independent channels, setups that can be simultaneously loaded into RAM: > 100, traces can be assigned to diagrams as required. Display: 21 cm (8.4") diagonal color LCD. Options. ZVB8-B21 1302.5480.02), Generator Step Attenuator for Port 1. ZVB8-B22 1302.5073.02), Generator Step Attenuator for Port 2. ZVB8-B23 1302.5496.02), Generator Step Attenuator for Port 3. ZVAB-K2 1164.1657.02), Time Domain. ZVB-K3 1164.1592.02), Mixer and Harmonic Measurements.



 

Standard Calibration $540.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ROHDE & SCHWARZ ZVB4. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Adjacent Channel Power
Adjacent Channel Power is the power from a modulated communications channel that leaks into an adjacent channel. This leakage is usually specified as a ratio to the power in the main channel, but is sometimes an absolute power.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.


Please contact us for your ROHDE & SCHWARZ ZVB4 CALIBRATION and/or ROHDE & SCHWARZ ZVB4 4 GHz Vector Network Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: